GE Appliances Water Filters

GE Appliances holds active listings in all three directories we index โ€” but they are split: NSF lists its NSF/ANSI 42, 44 and 58 systems, while its NSF/ANSI 53 health-effects certification is held at IAPMO R&T.

Best for

  • Owners of a GE under-sink reverse-osmosis system, listed for lead, fluoride, arsenic, nitrate and cyst reduction
  • Buyers of a GE whole-house filter or softener, listed under NSF/ANSI 42 and NSF/ANSI 44
  • Anyone checking a GE certification claim, where the answer depends on which directory you search

Not recommended for

  • Buyers who read a GE refrigerator filter's NSF/ANSI/CAN 372 row as a lead-reduction claim โ€” it is a material standard
  • Anyone searching NSF alone: GE's 53, 401, 177, P231 and P473 listings are all held at IAPMO R&T
  • Households that need a per-contaminant scope for the health-effects files, which the directory record does not itemize
Mid tier โ€” typically $200โ€“$500
  • Certs:NSF/ANSI 42, 44, 53, 58, 61, 177, 372, 401, NSF P231, NSF P473
  • 10 SKUs
  • Parent:Haier (listee of record: GE Appliances, a Haier Company)

Certification Reality: What's Actually Tested

This table shows the NSF/IAPMO/WQA-listed certifications for each GE Appliances SKU we tracked, alongside the contaminants the brand markets but which do not appear on the third-party listing. Green chips are third-party verified; amber chips are marketing claims without a corresponding listing. Every row links to the live certifier database so you can verify the listed claim set yourself.

GXRV40TBN

Under-sink reverse osmosis (GNRQ18NBN / GXRQ18NBN / GXRV40TBN) โ€” listed by NSF, and by IAPMO R&T as file WC-9859

Standards held

Performance

NSF/ANSI 42
NSF/ANSI 58

Whatโ€™s certified

  • Lead reduction (NSF/ANSI 58)
  • Fluoride reduction (NSF/ANSI 58)
  • Arsenic (pentavalent) reduction at or below 300 ppb (NSF/ANSI 58)
  • Nitrate and nitrite reduction (NSF/ANSI 58)
  • Cysts (NSF/ANSI 58)
  • Hexavalent chromium reduction (NSF/ANSI 58)
  • Trivalent chromium reduction (NSF/ANSI 58)
  • Barium, cadmium, copper and selenium reduction (NSF/ANSI 58)
  • Asbestos, turbidity and total dissolved solids reduction (NSF/ANSI 58)
  • Radium 226/228 reduction (NSF/ANSI 58)
  • Chlorine and taste and odor reduction (NSF/ANSI 42)

Brand claims but NOT certified

No discrepancy

We have not audited GE's marketing copy in this pass, so this column reports nothing rather than a finding of no gap. What we did verify is the listing: the arsenic claim is conditional โ€” it applies only to supplies at or below the referenced concentration and valency, so it is not a general arsenic guarantee.

Read more

NSF listing

View NSF listing

W-9756

IAPMO R&T files W-9756 and WC-11734 โ€” water treatment product, health effects. GE's NSF/ANSI 53 certification, and it is not in NSF's directory

Standards held

Performance

NSF/ANSI 53

Whatโ€™s certified

  • Health effects โ€” the directory record names the standard and the product category, and does not itemize the contaminants

Brand claims but NOT certified

No discrepancy

This is the row a reader who searched only NSF would never see. NSF returns no NSF/ANSI 53 section for GE Appliances; IAPMO R&T returns two Active ones. IAPMO R&T certifies against the same NSF/ANSI standards, so these are equivalent third-party certifications. What the directory does not give is the contaminant scope of each file, so we do not publish one โ€” ask GE for the certificate to see which contaminants a specific product covers.

Read more

NSF listing

View NSF listing

W-9758

IAPMO R&T files W-9758 / WC-11735 (emerging compounds) and W-11362 / WC-11736 (PFOA and PFOS)

Standards held

Performance

NSF/ANSI 401
NSF P473

Whatโ€™s certified

  • PFOA and PFOS (NSF P473)
  • Emerging compounds and incidental contaminants (NSF/ANSI 401)

Brand claims but NOT certified

No discrepancy

NSF P473 is the PFOA and PFOS protocol; NSF/ANSI 401 is the wider emerging-compounds set. Both of GE's are held at IAPMO R&T, and neither appears in NSF's results for this company. The files do not say which GE products they cover, so match the file to your specific model before assuming your filter is in scope.

Read more

NSF listing

View NSF listing

WQA-refrigerator-filter

GE refrigerator filter โ€” WQA row. NSF/ANSI 42 performance plus NSF/ANSI/CAN 372 material content

Standards held

Performance

NSF/ANSI 42

Material & component safety

NSF/ANSI 372

Whatโ€™s certified

  • Aesthetic chlorine (NSF/ANSI 42)
  • Nominal particulate, Class V (NSF/ANSI 42)

Brand claims but NOT certified

No discrepancy

The trap on this row: NSF/ANSI/CAN 372 is a lead CONTENT standard. It certifies that the part itself is lead-free as a material โ€” it is not a claim that the filter reduces lead in your water. That claim would be NSF/ANSI 53, and it is not on this row. The listed performance here is aesthetic chlorine and nominal particulate Class V.

Read more

NSF listing

View NSF listing

GXWH60T

Whole-house filtration (GXWH60T, GXMH31H) and cation-exchange softeners (GXSF30V, GXSH40V, GXSH45V, GXSHC40N)

Standards held

Performance

NSF/ANSI 42
NSF/ANSI 44

Whatโ€™s certified

  • Chlorine reduction (NSF/ANSI 42)
  • Taste and odor reduction (NSF/ANSI 42)
  • Hardness reduction (NSF/ANSI 44)
  • Barium reduction (NSF/ANSI 44)
  • Radium 226/228 reduction (NSF/ANSI 44)
  • Efficiency rated (NSF/ANSI 44)

Brand claims but NOT certified

No discrepancy

A whole-house GE unit is listed for aesthetic effects, not for health effects. NSF/ANSI 42 covers chlorine, taste and odor; NSF/ANSI 44 covers hardness, barium and radium on a softener. If you need certified reduction of lead, fluoride, arsenic or nitrate, that sits on the under-sink reverse-osmosis line, not on these.

Read more

NSF listing

View NSF listing

Check Certification for a GE Appliances Filter

This widget shows the third-party-listed certifications for GE Appliances SKUs only. Type a model number to filter the list below โ€” every result links to the full breakdown. To search across every brand we track, use the global certification tool.

NSF/ANSI 428 modelsNSF/ANSI 446 modelsNSF/ANSI 584 modelsNSF/ANSI 3723 modelsNSF/ANSI 532 modelsNSF P4732 modelsNSF/ANSI 4012 modelsNSF/ANSI 611 modelNSF/ANSI 1771 modelNSF P2311 model
  • GNRQ18NBN[1]

    GE Appliances, a Haier Company

    NSF/ANSI 42, 58
    View details
  • GXRQ18NBN[1]

    GE Appliances, a Haier Company

    NSF/ANSI 42, 58
    View details
  • GXRV40TBN[1]

    GE Appliances, a Haier Company

    NSF/ANSI 42
    View details
  • GXMH31H

    GE Appliances, a Haier Company

    NSF/ANSI 42
    View details
  • GXWH60T

    GE Appliances, A Haier Company

    NSF/ANSI 42
    View details
  • GXRV40TBN

    GE Appliances, a Haier Company

    NSF/ANSI 58
    View details
  • GXMH31H[2]

    GE Appliances, a Haier Company

    NSF/ANSI 44
    View details
  • GXSF30V[2]

    GE Appliances, a Haier Company

    NSF/ANSI 44
    View details
  • GXSH40V[2]

    GE Appliances, a Haier Company

    NSF/ANSI 44
    View details
  • GXSH45V[2]

    GE Appliances, a Haier Company

    NSF/ANSI 44
    View details
  • GXSHC40N[2]

    GE Appliances, a Haier Company

    NSF/ANSI 44
    View details
  • W-9755

    GE APPLIANCES, A HAIER COMPANY

    NSF/ANSI 42
    View details
  • WC-9892

    GE APPLIANCES, A HAIER COMPANY

    NSF/ANSI 42
    View details
  • W-9756

    GE APPLIANCES, A HAIER COMPANY

    NSF/ANSI 53
    View details
  • WC-11734

    GE APPLIANCES, A HAIER COMPANY

    NSF/ANSI 53
    View details
  • WC-9859

    GE APPLIANCES, A HAIER COMPANY

    NSF/ANSI 58
    View details
  • K-13334

    GE APPLIANCES, A HAIER COMPANY

    NSF/ANSI 61
    View details
  • K-13335

    GE APPLIANCES, A HAIER COMPANY

    NSF/ANSI 372
    View details
  • W-9757

    GE APPLIANCES, A HAIER COMPANY

    NSF/ANSI 372
    View details
  • W-11362

    GE APPLIANCES, A HAIER COMPANY

    NSF P473
    View details
  • WC-11736

    GE APPLIANCES, A HAIER COMPANY

    NSF P473
    View details
  • W-29819

    GE APPLIANCES, A HAIER COMPANY

    NSF/ANSI 44
    View details
  • W-14289

    GE APPLIANCES, A HAIER COMPANY

    NSF/ANSI 177
    View details
  • W-9758

    GE APPLIANCES, A HAIER COMPANY

    NSF/ANSI 401
    View details
  • WC-11735

    GE APPLIANCES, A HAIER COMPANY

    NSF/ANSI 401
    View details
  • WC-13808

    GE APPLIANCES, A HAIER COMPANY

    NSF P231
    View details
  • GXRTDR

    GE Appliances, a Haier Company. Water Filtration Systems

    NSF/ANSI 42, 372
    View details

Listings as of Jun 4, 2026.

About GE Appliances

GE Appliances is certified โ€” but you have to look in more than one place to see it. NSF's drinking water treatment unit directory lists the company under NSF/ANSI 42 (chlorine, taste and odor), NSF/ANSI 44 (softeners) and NSF/ANSI 58 (reverse osmosis), plus CSA B483.1. That same search returns no NSF/ANSI 53 section at all.

IAPMO R&T does. Its listee record for GE Appliances carries 18 files, every one of them Active, including two NSF/ANSI 53 health-effects listings (W-9756 and WC-11734) and files for NSF/ANSI 401, NSF/ANSI 177, NSF P231, NSF P473, NSF/ANSI/CAN 61 and NSF/ANSI/CAN 372.

WQA adds three more rows, one of them a refrigerator filter certified to NSF/ANSI/CAN 372.

  • IAPMO R&T and WQA certify against the same NSF/ANSI standards NSF does. A listing from either is an equivalent third-party certification, not a lesser one โ€” UL Solutions and CSA Group certify to these standards too.
  • So "GE is not NSF certified for health effects" is a false conclusion drawn from a partial search. The certification exists; the certifier is IAPMO R&T.
Founded:Not verified โ€” the certifier records carry no founding date
Headquarters:Appliance Park AP2-120, Louisville, Kentucky, USA
Parent company:Haier (listee of record: GE Appliances, a Haier Company)

Under-sink reverse osmosis (GNRQ18NBN, GXRQ18NBN, GXRV40TBN)

The broadest certified scope in the GE line, and the only place a certified lead reduction claim appears.

  • Listed by NSF under NSF/ANSI 58 for arsenic (pentavalent, at or below 300 ppb), asbestos, barium, cadmium, hexavalent and trivalent chromium, copper, cysts, fluoride, lead, nitrate and nitrite, radium 226/228, selenium, total dissolved solids and turbidity.
  • Also NSF/ANSI 42 for chlorine and taste and odor, and CSA B483.1.
  • Rated production: 14.76 gallons per day on modules FQ18MN / FQ18PN.
  • Also listed at IAPMO R&T as file WC-9859, water conditioners (reverse osmosis), NSF/ANSI 58.

Whole-house filtration (GXWH60T, GXMH31H)

Point-of-entry housings listed for aesthetic effects only.

  • GXWH60T โ€” NSF/ANSI 42 chlorine and taste and odor, element FXWPX, 15,000 gallons at 4 gpm, plus CSA B483.1.
  • GXMH31H โ€” NSF/ANSI 42 chlorine and taste and odor, 570,000 gallons at 8 gpm.
  • Neither carries a health-effects claim at NSF; NSF/ANSI 42 covers taste, odor and chlorine, not contaminant reduction.

Cation-exchange water softeners (GXSF30V, GXSH40V, GXSH45V, GXSHC40N, GXMH31H)

Softeners, listed by NSF under NSF/ANSI 44.

  • Listed claims: hardness reduction, barium reduction, radium 226/228 reduction, and efficiency rated.
  • Service flow: 7.5 gpm (GXSF30V), 8 gpm (GXMH31H) and 9.5 gpm (GXSH40V, GXSH45V, GXSHC40N).
  • Also at IAPMO R&T as file W-29819, residential cation exchange water softeners, NSF/ANSI 44.

Refrigerator filters

The highest-volume GE filter category, and the one most often misread.

  • WQA lists a GE refrigerator filter under NSF/ANSI 42 for aesthetic chlorine and nominal particulate Class V.
  • The same product's other WQA row is NSF/ANSI/CAN 372 โ€” lead content, meaning the part is lead-free as a material. That is not a lead-reduction claim.
  • A certified lead reduction claim on a GE product appears on the under-sink reverse-osmosis systems above, under NSF/ANSI 58.

Shower filtration and microbiological purifiers (IAPMO R&T files)

Two categories that appear only in IAPMO R&T's results for this company.

  • W-14289 โ€” shower filtration systems, aesthetic effects, NSF/ANSI 177.
  • WC-13808 โ€” microbiological water purifiers, NSF P231.
  • Both are Active. Neither appears in NSF's own results for GE Appliances, which is why a single-directory search understates this brand.

NSF's record puts GE Appliances at Appliance Park AP2-120, Louisville, Kentucky 40225, and names three manufacturing facilities on the GE listings: Iuka, Mississippi; Ripley, Mississippi; and Pingtung, Taiwan.

The directory does not attribute individual model numbers to individual plants, so we do not publish a per-SKU country of origin.

The facility list is part of the listing itself: where a certified product is built is inside the scope a certifier audits, which is one of the practical differences between a certified product and one that is merely tested once.

GE Appliances products we have verified

Each page checks the model's certification listings live in the NSF, IAPMO R&T and WQA directories, separates what the brand claims from what a certifier has listed, and prices ten years of ownership.

Which GE Appliances Filter Is Right for You?

We mapped each GE Appliances SKUโ€™s NSF-listed certifications against the 10 contaminants people search for most. Where GE Appliances doesnโ€™t have a certified SKU, we say so.

Lead
Best pick: Under-sink reverse osmosis (GNRQ18NBN / GXRQ18NBN / GXRV40TBN) โ€” listed by NSF, and by IAPMO R&T as file WC-9859 โ€” certified for Lead (GE Appliances).
PFAS
Best pick: IAPMO R&T files W-9758 / WC-11735 (emerging compounds) and W-11362 / WC-11736 (PFOA and PFOS) โ€” certified for PFAS (GE Appliances).
Fluoride
Best pick: Under-sink reverse osmosis (GNRQ18NBN / GXRQ18NBN / GXRV40TBN) โ€” listed by NSF, and by IAPMO R&T as file WC-9859 โ€” certified for Fluoride (GE Appliances).
Arsenic
Best pick: Under-sink reverse osmosis (GNRQ18NBN / GXRQ18NBN / GXRV40TBN) โ€” listed by NSF, and by IAPMO R&T as file WC-9859 โ€” certified for Arsenic (GE Appliances).
Nitrate
Best pick: Under-sink reverse osmosis (GNRQ18NBN / GXRQ18NBN / GXRV40TBN) โ€” listed by NSF, and by IAPMO R&T as file WC-9859 โ€” certified for Nitrate (GE Appliances).
Chromium-6
Best pick: Under-sink reverse osmosis (GNRQ18NBN / GXRQ18NBN / GXRV40TBN) โ€” listed by NSF, and by IAPMO R&T as file WC-9859 โ€” certified for Chromium-6 (GE Appliances).
Mercury
Not the right choice if Mercury is your priority โ€” no certified GE Appliances SKU for Mercury. Consider an NSF/ANSI 53-listed filter.
Atrazine
Not the right choice if Atrazine is your priority โ€” no certified GE Appliances SKU for Atrazine. Consider an NSF/ANSI 53-listed filter.
Chloroform
Not the right choice if Chloroform is your priority โ€” no certified GE Appliances SKU for Chloroform. Consider an NSF/ANSI 53-listed filter.
Cysts
Best pick: Under-sink reverse osmosis (GNRQ18NBN / GXRQ18NBN / GXRV40TBN) โ€” listed by NSF, and by IAPMO R&T as file WC-9859 โ€” certified for Cysts (GE Appliances).

How GE Appliances Compares

GE Appliances at NSF vs GE Appliances at IAPMO R&T

NSF/ANSI 42 โ€” aesthetic effects

GE Appliances at NSF

Yes (GNRQ18NBN, GXRQ18NBN, GXRV40TBN, GXMH31H, GXWH60T)

GE Appliances at IAPMO R&T

Yes (files W-9755, WC-9892)

NSF/ANSI 44 โ€” softeners

GE Appliances at NSF

Yes (GXMH31H, GXSF30V, GXSH40V, GXSH45V, GXSHC40N)

GE Appliances at IAPMO R&T

Yes (file W-29819)

NSF/ANSI 53 โ€” health effects

GE Appliances at NSF

No section returned for this manufacturer

GE Appliances at IAPMO R&T

Yes โ€” W-9756 and WC-11734, both Active

NSF/ANSI 58 โ€” reverse osmosis

GE Appliances at NSF

Yes (GNRQ18NBN, GXRQ18NBN, GXRV40TBN, 14.76 gpd)

GE Appliances at IAPMO R&T

Yes (file WC-9859)

NSF/ANSI 401 โ€” emerging compounds

GE Appliances at NSF

Not in the results

GE Appliances at IAPMO R&T

Yes โ€” W-9758 and WC-11735

NSF P473 โ€” PFOA and PFOS

GE Appliances at NSF

Not in the results

GE Appliances at IAPMO R&T

Yes โ€” W-11362 and WC-11736

NSF/ANSI 177 โ€” shower filtration

GE Appliances at NSF

Not in the results

GE Appliances at IAPMO R&T

Yes โ€” W-14289

NSF P231 โ€” microbiological purifiers

GE Appliances at NSF

Not in the results

GE Appliances at IAPMO R&T

Yes โ€” WC-13808

Files or products returned

GE Appliances at NSF

6 manufacturers / 20 products on the company search

GE Appliances at IAPMO R&T

18 files, all Active

Bottom line: the two directories give different answers about the same company, and only one of them is complete.

  • Search NSF alone and GE looks like an aesthetic-effects and softener brand with one reverse-osmosis line. No health-effects certification, no PFAS protocol, no emerging compounds.
  • Search IAPMO R&T and four more standards appear, including two Active NSF/ANSI 53 health-effects files.

Both bodies certify against the same NSF/ANSI standards, so neither listing outranks the other. The practical rule: check every directory before concluding a brand is uncertified for something.

Sources for facts in this comparison

  1. NSF listingaccessed: 2026-08-25
    https://info.nsf.org/Certified/dwtu/listings.asp?CompanyName=GE+Appliances&submit1=Search+by+Manufacturer&Program=DWTU
    • GE Appliances sections under NSF/ANSI 42, 44, 58 and CSA B483.1, with no NSF/ANSI 53 section
    • Company search footer reports 6 matching manufacturers and 20 matching products
  2. IAPMO listingaccessed: 2026-08-24
    https://pld.iapmo.org/
    • 18 Active files under the GE Appliances listee across NSF/ANSI 42, 44, 53, 58, 177, 401, NSF P231, NSF P473, NSF/ANSI/CAN 61, NSF/ANSI/CAN 372 and CSA B483.1

GE under-sink reverse osmosis vs GE refrigerator filter

Certifier and record

GE under-sink reverse osmosis

NSF (GNRQ18NBN, GXRQ18NBN, GXRV40TBN)

GE refrigerator filter

WQA (refrigerator filter row)

Standards held

GE under-sink reverse osmosis

NSF/ANSI 42 and NSF/ANSI 58, plus CSA B483.1

GE refrigerator filter

NSF/ANSI 42 and NSF/ANSI/CAN 372

Certified lead reduction

GE under-sink reverse osmosis

Yes โ€” lead is a listed NSF/ANSI 58 claim

GE refrigerator filter

No โ€” NSF/ANSI/CAN 372 is lead content, not lead reduction

Certified fluoride, arsenic, nitrate

GE under-sink reverse osmosis

Yes โ€” all three are listed NSF/ANSI 58 claims

GE refrigerator filter

Not listed

Chlorine, taste and odor

GE under-sink reverse osmosis

Yes (NSF/ANSI 42)

GE refrigerator filter

Yes โ€” aesthetic chlorine (NSF/ANSI 42)

Particulate

GE under-sink reverse osmosis

Turbidity reduction (NSF/ANSI 58)

GE refrigerator filter

Nominal particulate, Class V (NSF/ANSI 42)

Rated output

GE under-sink reverse osmosis

14.76 gallons per day

GE refrigerator filter

Not stated on the directory row

Bottom line: if lead is why you are buying, the refrigerator filter is not the GE product that covers it.

  • The NSF/ANSI/CAN 372 badge on a refrigerator filter is a materials claim. It says the part is lead-free โ€” that it will not add lead to your water. It says nothing about taking lead out.
  • Certified lead reduction on a GE product sits on the under-sink reverse-osmosis systems, under NSF/ANSI 58, along with fluoride, arsenic, nitrate and cyst claims.

The refrigerator filter is still a genuine NSF/ANSI 42 listing for chlorine and particulate. It is just a different job.

Sources for facts in this comparison

  1. NSF listingaccessed: 2026-08-25
    https://info.nsf.org/Certified/dwtu/listings.asp?CompanyName=GE+Appliances&submit1=Search+by+Manufacturer&Program=DWTU
    • NSF/ANSI 58 listed claims on GNRQ18NBN, GXRQ18NBN and GXRV40TBN include lead, fluoride, arsenic (pentavalent), nitrate and nitrite, cysts and turbidity, at 14.76 gpd
  2. WQA listingaccessed: 2026-08-24
    https://find.wqa.org/find-products#/keyword/GE%20Appliances
    • The GE refrigerator-filter row is NSF/ANSI/CAN 372, lead content, in WQA's Lead Free category
    • The GE point-of-use row is NSF/ANSI 42 with aesthetic chlorine and nominal particulate Class V reduction claims

What Reddit Says About GE Appliances

Community signals for GE Appliances are being researched โ€” check back soon.

About GE Appliances Marketing Language

Some claims on GE Appliances packaging and product pages are frequently confused with what the underlying third-party certifications actually cover. The note below documents one such mismatch with primary-source citations so you can verify the specifics yourself.

GE's NSF/ANSI 53 health-effects certification is real. It is listed at IAPMO R&T, not in NSF's own directory โ€” and a lead-free refrigerator filter is not a lead-reduction filter.

Two different things get confused on this brand, and both of them matter.

One: the directory you search decides the answer you get. NSF's drinking water treatment unit directory returns no NSF/ANSI 53 section for GE Appliances. IAPMO R&T returns two Active NSF/ANSI 53 files, W-9756 and WC-11734, plus NSF/ANSI 401, NSF/ANSI 177, NSF P231 and NSF P473 files that NSF's results for this company do not show. IAPMO R&T and WQA certify against the same NSF/ANSI standards; UL Solutions and CSA Group certify to them too. A listing from any accredited body is a third-party certification, so "not on NSF's site" is not the same as "not certified".

Two: NSF/ANSI/CAN 372 is not NSF/ANSI 53. WQA lists a GE refrigerator filter in its Lead Free category under NSF/ANSI/CAN 372. That standard governs how much lead the product's own materials may contain โ€” it certifies the part will not add lead to your water. Reducing lead already in your water is NSF/ANSI 53, a different standard with a different test. On GE's records, the certified lead reduction claim is on the under-sink reverse-osmosis systems under NSF/ANSI 58.

  • Before you buy on a lead claim, check which standard the badge names, and which product the listing covers.
  • Before you conclude a brand is uncertified, check all the directories, not just the best-known one.

Sources

  1. NSF listingaccessed: 2026-08-25
    https://info.nsf.org/Certified/dwtu/listings.asp?CompanyName=GE+Appliances&submit1=Search+by+Manufacturer&Program=DWTU
    • No NSF/ANSI 53, 401, 177, P231 or P473 section is returned for GE Appliances on NSF's company-scoped search
  2. IAPMO listingaccessed: 2026-08-24
    https://pld.iapmo.org/
    • W-9756 and WC-11734 are Active NSF/ANSI 53 health-effects files under the GE Appliances listee, alongside NSF/ANSI 401, NSF/ANSI 177, NSF P231 and NSF P473 files
  3. WQA listingaccessed: 2026-08-24
    https://find.wqa.org/find-products#/keyword/GE%20Appliances
    • The GE refrigerator-filter row sits in WQA's Lead Free category under NSF/ANSI/CAN 372, drinking water system components - lead content

Verified 2026-08-25.

Frequently Asked Questions About GE Appliances Water Filters

Partly โ€” and the rest are certified by IAPMO R&T, which amounts to the same thing. NSF's drinking water treatment unit directory lists GE Appliances under NSF/ANSI 42 (chlorine, taste and odor), NSF/ANSI 44 (softeners) and NSF/ANSI 58 (reverse osmosis), plus CSA B483.1.

It returns no NSF/ANSI 53 health-effects section for the company. IAPMO R&T does: files W-9756 and WC-11734, both Active, plus NSF/ANSI 401, NSF/ANSI 177, NSF P231 and NSF P473. WQA lists three more GE rows.

IAPMO R&T and WQA are accredited certification bodies that certify against the same NSF/ANSI standards, and UL Solutions and CSA Group certify to them as well, so a listing from any of them is a third-party certification.

You can search GE Appliances on NSF's directory yourself, then check your water quality by ZIP code to see which of those contaminants your supply actually has.

Sources: [1] [2]

How We Researched GE Appliances

Our brand assessments follow a four-tier source ladder. We start with Tier 1 primary sources โ€” NSF International, IAPMO, and WQA certification listings, plus SEC filings and EPA records โ€” to establish what is third-party verified. We then layer in brand-official statements (corporate sites, datasheets, support pages) for context, tier-1 journalism for independent reporting, and community signals (Reddit threads, Amazon reviews) for real-world ownership experience. Every claim on this page traces back to one of the citations below.

Reviewed by TapWaterData Editorial.

Last full review: 2026-08-25 ยท Next scheduled review: 2027-08-25

All sources (5)

  1. NSF listingAccessed 2026-08-25
    https://info.nsf.org/Certified/dwtu/listings.asp?CompanyName=GE+Appliances&submit1=Search+by+Manufacturer&Program=DWTU

    GE Appliances sections under NSF/ANSI 42 (chlorine, taste and odor), NSF/ANSI 44 (barium, efficiency rated, hardness, radium 226/228), NSF/ANSI 58 (the 15-claim reverse-osmosis set including lead, fluoride, arsenic and nitrate) and CSA B483.1 ยท No NSF/ANSI 53 section is returned for this manufacturer; the company search footer reports 6 matching manufacturers and 20 matching products

  2. NSF listingAccessed 2026-08-25
    https://info.nsf.org/Certified/dwtu/listings.asp?CompanyName=GE+Appliances&submit1=Search+by+Manufacturer&Program=DWTU

    Address of record: Appliance Park AP2-120, Louisville, KY 40225 ยท Manufacturing facilities named on the listings: Iuka MS, Ripley MS, and Pingtung, Taiwan ยท Rated capacities: FQ18PN element 260 gallons at 0.5 gpm, module production 14.76 gpd, GXWH60T 15,000 gallons at 4 gpm, GXMH31H 570,000 gallons at 8 gpm, softener service flows 7.5 to 9.5 gpm

  3. IAPMO listingAccessed 2026-08-24
    https://pld.iapmo.org/

    Listee 'GE APPLIANCES, A HAIER COMPANY' carries 18 files, all Active ยท NSF/ANSI 53 health-effects files W-9756 (2021) and WC-11734 (2022) โ€” the certification absent from NSF's own results

  4. IAPMO listingAccessed 2026-08-24
    https://pld.iapmo.org/

    NSF/ANSI 401 files W-9758 and WC-11735; NSF P473 PFOA and PFOS files W-11362 and WC-11736; NSF/ANSI 177 shower file W-14289; NSF P231 microbiological file WC-13808 ยท NSF/ANSI/CAN 61 file K-13334, NSF/ANSI/CAN 372 file K-13335, NSF/ANSI 372 file W-9757, NSF/ANSI 42 files W-9755 and WC-9892, NSF/ANSI 44 file W-29819, NSF/ANSI 58 file WC-9859, CSA B483.1 files W-9975 and WC-15030

  5. WQA listingAccessed 2026-08-24
    https://find.wqa.org/find-products#/keyword/GE%20Appliances

    Three rows under 'GE Appliances, a Haier Company. Water Filtration Systems': CSA B483.1; NSF/ANSI 42 point-of-use with aesthetic chlorine and nominal particulate Class V; and a refrigerator filter under NSF/ANSI/CAN 372, lead content ยท The NSF/ANSI/CAN 372 row carries no reduction claims โ€” it is a material standard, not a lead-reduction performance listing

TapWaterData is independent and not affiliated with NSF International, IAPMO, or WQA.