Skip to main content
Waterd — free hydration appGet

What Does "Not Detected" Mean on a Water Test?

ND isn't zero. We read a real New Jersey well report row by row: how low the test could see, what wasn't on the list, and a tiny-looking number that was four times EPA's limit.

10 min read
By TapWaterData Team

"Not detected" (ND) means the lab didn't detect the substance above the limit it uses for that test, usually printed as a reporting limit. It does not prove zero. Whether an ND is good news depends on three things: how low the test could see, what it tested for, and which sample it tested.

This fall we read five real lab reports from New Jersey private wells, row by row, with every name, address and ID removed. New Jersey requires a long, fixed test list for wells, and these reports print the reporting limits and state standards beside each result. Most rows say "<" something. Here's what those rows tell you, and what they don't. The same reading works for a lab test of city water.

✅ The short version:

  • ND and "<" don't mean "none." They mean "below the lab's limit." Find that limit, usually in a column called Reporting Limit.
  • Check the limit against the water standard. Our sample lab report could see lead down to 1 part per billion (ppb). Most home lead kits in a 2021 study couldn't reliably detect lead below 5,000 ppb.
  • Read the units first. One report showed PFOA at 0.016 µg/L (micrograms per liter). That's 16 parts per trillion: four times EPA's limit.
  • No row, no result. If a substance isn't on your report, you have no result for it. Ask whether it was tested.
  • The sample matters. Untreated water, a flushed tap and a single day each answer a narrower question than "is my water safe?"

What does "not detected" mean on a water test?

Think of a kitchen scale that only registers 5 grams or more. Put a paperclip on it and it reads zero. The paperclip is still there; the scale just can't weigh anything that light.

Chemical tests work in a similar way. Each result has a limit below which the lab can't measure reliably. Below it, labs print "ND" or "<" followed by the limit, and some print a less certain number instead. As Virginia Cooperative Extension says, "'Non-detected' does not necessarily mean the analyte is not present". The analyte is simply the substance being tested.

What's the difference between a detection limit and a reporting limit?

Chemical results can involve two different limits, and they're easy to mix up:

Labs differ on which limit they use for "ND." Your report's notes or legend should say.

What do ND, the less-than sign and J mean on a water test?

What you see What it means
ND Not detected. Find the limit and its units in the reporting-limit column or the report's notes.
<1.00 Less than 1.00, in the units shown. Not a measured amount, and not proof of zero.
A number below the reporting limit (0.00055 next to a 0.0020 limit) Some labs mark these "J," meaning estimated. No letter? Treat it as less certain, and ask the lab how to read it.
A number at or above the reporting limit (6.6) A measured amount. Compare it with the water standard, in the same units.
Absent / Present A yes-or-no test for the bacteria named on that row, in the 100 milliliters tested. Read total coliform and E. coli separately. E. coli present? Don't drink the water; call your local health department.
± (3.78 ± 2.476) The lab's uncertainty: the likely range around its estimate. Common on radiation tests.

How do you read a well-water lab report?

Start with one row. These six columns explain the PFOA result from the October 2026 report. PFOA is one of the PFAS chemicals, often called "forever chemicals." (For health effects and treatment, see our PFOA overview.)

One report row, explained A PFOA row from a New Jersey private-well lab report. Analyte: PFOA. Method: EPA 537.1. Reporting limit: 0.0020 micrograms per liter, which is 2 parts per trillion. Units: micrograms per liter. Standard printed: 0.014 micrograms per liter, New Jersey's limit of 14 parts per trillion; EPA's limit is 4. Result: 0.0010 micrograms per liter, which is 1 part per trillion. That is below the lab's own reporting limit, so it is less certain than a result above it; the printed value is below both limits. One report row, explained New Jersey private well, Oct 2026. Redrawn; identifying details removed. On the report What it means Analyte Method Reporting limit Units MCL Result PFOA EPA 537.1 0.0020 µg/L 0.014 µg/L 0.0010 What they looked for. PFOA, one of the PFAS "forever chemicals." How. The EPA testing procedure the lab followed. Reporting limit: 2 ppt. Below it, the lab prints "<" or a less certain number. Micrograms per liter (= ppb). Multiply by 1,000 for parts per trillion (ppt). Water standard used: 14 ppt. New Jersey's legal limit. EPA's for public water: 4 ppt. What they found: 1 ppt. Below the reporting limit, so less certain than a number above it. The printed value is below both limits.

Five more rows from the same report:

  • Lead: <1.00 µg/L. Below 1 ppb, a sensitive cutoff. But for lead, New Jersey's rules call for untreated well water, flushed for at least two minutes until its temperature changes. The report's own footnote says the first-draw sample used for EPA's lead action level "is NOT required" by New Jersey's well-testing rules. This sample is meant to check the well water. It doesn't show what your faucet or pipes may add while water sits overnight. Our lead guide explains the plumbing connection.
  • PFOS: 0.00055 µg/L. Another PFAS chemical. About 0.55 parts per trillion (ppt), below the 2 ppt reporting limit, printed with no letter. Some labs would mark it "J" for estimated. Treat it as less certain than results above the limit, and ask the lab whether it's an estimated detection.
  • Arsenic: 6.6 µg/L. Detected: 6.6 ppb. That's above New Jersey's 5 ppb limit, though below EPA's 10 ppb. The report ticked the box "One or more of the analytical results do not meet primary contaminant standards for drinking water." This was the result that mattered most. For arsenic above its standard, New Jersey advises bottled or properly treated water for drinking and cooking in the meantime. Boiling doesn't remove arsenic.
  • 26 volatile organic compounds (VOCs), such as solvents and fuel chemicals: all <0.500 µg/L. The lowest standard New Jersey sets for any of them is 1 ppb, so this reporting limit sits below every standard. That's an ND you can lean on.
  • Total coliform and E. coli: Absent. Neither was found in the 100 mL tested. Standard Methods says to report them as "present or absent in 100-mL sample." EPA calls absence a "reduced likelihood" of fecal contamination, not proof that no germs are present. The result covers that day's sample.

Is the lab's limit low enough to matter?

This is the first question to ask of any ND. A reporting limit tells you the smallest amount a test reports reliably. If the water standard you're checking sits below that limit, "not detected" can't tell you which side of it you're on.

Lead shows the gap best. A 2021 peer-reviewed study checked 16 home lead test kit brands. Twelve "were not suitable for drinking water analysis, with lead detection limits of 5-20 mg/L." That's 5,000 to 20,000 ppb. In the study's particle tests, the strip brand used picked up dissolved lead but missed lead in particle form.

How much lead can each test detect? A ladder of lead values in parts per billion, not to scale. Our sample lab report's reporting limit is 1 ppb, its cutoff for reporting a reliable number. Most home lead kits in a 2021 study had detection limits of 5,000 to 20,000 ppb, so they cannot reliably detect lead below that, including New Jersey's 5 ppb well standard and EPA's 15 ppb action level for utilities, which drops to 10 ppb in November 2027. EPA's health goal for lead is zero. How much lead can each test detect? In parts per billion (ppb). Not to scale. LabKits 5,000+ 15 5 1 0 Detection limits of most home lead kits in a 2021 study (up to 20,000 ppb) EPA action level for utilities (10 ppb from Nov 2027). It triggers action; it isn't a safe level. New Jersey's standard for a well sample taken after running the tap Reporting limit on our sample lab report EPA's health goal for lead at or above the test's limit below the test's limit

A lab result of <1 ppb is below both 5 and 15. A kit with a 5,000 ppb detection limit can't show whether you're above or below 15. Both can give a negative result. (Our strip test vs lab test guide covers what strips are good for.)

Two kinds of comparison value show up on reports. A legal limit, the maximum contaminant level (MCL), is the most a public water system may deliver. A health goal (MCLG) is the level with no known or expected health risk. EPA's health goal is zero for lead, arsenic, PFOA and PFOS. No test can prove there's none, so for these an ND only tells you the lab found nothing above its limit. Our MCL vs MCLG guide explains the difference.

Why should you read the units first?

Because the smallest-looking number can be the biggest problem. Here's PFOA on two of the five reports:

PFOA on two real well reports, in parts per trillion A scale from 0 to 18 parts per trillion. The lab's reporting limit is about 2 ppt. Report A printed 0.0010 micrograms per liter, which is 1 ppt, below the lab's reporting limit. EPA's limit for public water is 4 ppt and New Jersey's is 14 ppt. Report C printed 0.016 micrograms per liter, which is 16 ppt, four times EPA's limit and above New Jersey's. PFOA on two real well reports, in ppt Same lab, same test. Both results converted to ppt (µg/L × 1,000). EPA limit 4 NJ limit 14 Report A 1 ppt Report C 16 ppt 024681012141618 below the reporting limit (about 2 ppt) Report A: 0.0010 µg/L = 1 ppt. Below the reporting limit. Report C: 0.016 µg/L = 16 ppt. 4× EPA's limit. EPA's health goal for PFOA is 0. Scale is linear.

Report C's 0.016 µg/L is 16 ppt: four times EPA's 4 ppt limit for PFOA in public water, and above New Jersey's 14 ppt. At a level like that, EPA suggests considering another water source for drinking and cooking while you sort out treatment. Boiling doesn't remove PFAS. EPA's own instruction: "To convert results in µg/L to nanograms/liter (ng/L, or parts per trillion), multiply the value by 1,000."

The cheat sheet:

Unit on the report Same as Typical use
mg/L (milligrams per liter) ppm, parts per million nitrate, iron, sodium
µg/L or ug/L (micrograms per liter) ppb, parts per billion lead, arsenic, solvents
ng/L (nanograms per liter) ppt, parts per trillion PFAS

To turn ppb into ppt, multiply by 1,000. To turn ppt into ppb, divide by 1,000. Put the result and the water standard in the same unit before you compare. Check each row's units: ours printed nitrate (as nitrogen) as 2260 µg/L, which is 2.26 mg/L, well under the 10 mg/L standard.

Which water standard does the report use?

The column labeled "MCL" on the New Jersey reports holds the state's standards, which the report says "may be more stringent" than federal ones. That's why arsenic at 6.6 ppb counted as a failure: New Jersey's limit is 5 ppb, EPA's is 10 ppb. For PFOA it runs the other way: New Jersey's 14 ppt is higher than EPA's 4 ppt.

Federal limits legally apply to public water systems, not private wells, though well owners commonly use them for comparison. EPA set its 4 ppt PFOA and PFOS limits in 2024, with water systems due to comply by April 26, 2029. A May 2026 proposal would let eligible systems ask for two more years. When a report says "pass," check which standard it used.

What wasn't tested?

"Not detected" only covers what's on the list. A substance missing from a lab report has no result there, which is a different thing from "not detected."

What one real report tested, and what it didn't list Tested on the sample New Jersey well report: total coliform and E. coli bacteria; arsenic, lead, iron, manganese and uranium; nitrate; pH; 26 volatile organic compounds such as solvents and fuel chemicals; 3 synthetic organic chemicals; 6 PFAS; and gross alpha radioactivity. Not on the report: copper; sodium; hardness; total dissolved solids, which EPA recommends testing yearly; radon in water; other PFAS, of which thousands exist; most pesticides; Legionella and most other germs; and mercury, which New Jersey requires only in 9 counties. What one report tested, and what it didn't list New Jersey Private Well Testing Act panel, sample report A ✓ Tested ✗ Not on this report Total coliform, E. coli Arsenic, lead, iron,manganese, uranium Nitrate, pH 26 volatile organiccompounds (VOCs) 3 synthetic chemicals,incl. 2 former soilfumigants 6 PFAS Gross alpha(radioactivity screen) Copper, sodium,hardness Total dissolved solids(on EPA's test-every-year list) Radon in water Other PFAS(EPA: "thousands" exist) Most pesticides Legionella, mostother germs Mercury(NJ requires it in9 counties)

Three gaps stand out:

City water has its own version of this. EPA guidance says "Only the results for detected contaminants may be included in the main water quality table" of your utility's annual Consumer Confidence Report (CCR). So a missing row can mean "tested, nothing found" or "not tested this year." Rules let utilities test some chemicals only once every 3 to 9 years, and results up to 5 years old can appear. A range printed in a CCR shows results across samples; it isn't the lab's detection limit. Our guides to reading your utility's water quality report and the CCR's tables walk through it.

Which sample did the lab test?

A lab tests the bottle it receives. As one of our reports puts it: "The report reflects the samples as received." Three things decide what's in that bottle:

  • Before or after treatment. New Jersey's rules call for untreated water, so the reports describe the well, not what comes out of a softener or filter. Three of the five homes also sent a treated sample, and it told a different story. One home's untreated water had PFOA at 7.6 ppt. After its PFAS treatment system, all six PFAS tested were below their reporting limits. If you have treatment, test the water you actually drink, and set a date to retest.
  • Flushed or first-draw. A flushed sample, taken after running the tap, is meant to check the water source. A first-draw sample is the first water out after it has sat in the pipes for at least 6 hours, so it can pick up lead from pipes and fixtures. New Jersey's well test uses a flushed sample. EPA's tap-sampling rules for utilities use first-draw water.
  • One day. Well water can change. A USGS study of wells sampled around rain and snowmelt found "one sample would have no detections and the next sample could be a relatively high concentration" of material from microbes. CDC advises testing after flooding or well repairs.

Why do the "<" numbers change from report to report?

Reporting limits can vary between samples. Across our five reports, the manganese limit was 5, 10 or 25 ppb, and the PFAS limit for water samples ran from 1.8 to 2.0 ppt. One common reason is dilution: when a sample has to be diluted, the limit rises with it. EPA's PFAS method says diluted results "must be documented as a dilution and MRLs adjusted accordingly". The reports don't say why each limit changed, so if a "<" value on your report looks high, ask.

You can also ask. The lab's terms on our reports say customers can request specific reporting limits before sample submission, and "Analytical cost may vary based upon reporting limits and / or data quality objectives." Tell the lab which water standard you need to check before you order.

What should you do with a "not detected" result?

  1. Find the limit. Look in the reporting-limit column or the legend. If your report says "ND" with no number anywhere, ask the lab for its limit.
  2. Compare the limit with the water standard. If the limit is above the standard, the test can't answer the question. Ask a state-certified lab for a test with a lower reporting limit; our certified-lab directory lists them by state.
  3. Check the units on every row. Convert to the same unit as the standard before you compare.
  4. Read the list. Note what's missing, and test for what matters where you live. CDC's well testing guidance and our private-well testing hub are good places to start.
  5. Check how the sample was taken. To check lead after water has sat in your pipes, ask the lab for first-draw sampling instructions.
  6. Retest on schedule. EPA and CDC both recommend testing a private well at least once a year for bacteria, nitrate, total dissolved solids and pH.

💡 Got a result on your report you can't decode? Upload your lab report and our team will send you a free plain-English reading. Or tell us which result confused you. We're collecting the most common ones for future guides.

For how often to retest a well, see our well-water testing schedule.

Sources

All read November 8, 2026. Sample reports: five New Jersey Private Well Testing Act certificates of analysis from a state-certified lab, November 2025 to October 2026, shared with TapWaterData. Names, addresses, lot and block numbers, lab identity and sample IDs removed.

Get the Weekly Water Brief

One email per week. EPA updates, filter deals, and what's actually in your water.

Free forever. Unsubscribe anytime. We never share your email.

Are you a business that needs water utility data?

We provide verified contacts for 4,385+ utilities.

Frequently Asked Questions

ND stands for "not detected." The lab did not detect the substance above the limit it uses for that test, usually a reporting limit or a detection limit. The report's notes say which. ND does not prove the amount was zero.

Get the Weekly Water Brief

One email a week on water testing, treatment, and what water-quality data means for your home.

One email a week. Unsubscribe anytime.