The water filters below are each shown with their certification listings: the certifier, the standard and the claims as listed. Idaho DEQ states that typical charcoal-based filters, such as pitcher filters, do not remove fluoride.

Do water filters remove fluoride?

Partly. Reverse osmosis systems can be certified for fluoride reduction under NSF/ANSI 58; typical charcoal-based filters do not remove fluoride.

Certification pass mark: To be certified for fluoride reduction under NSF/ANSI 58, a reverse osmosis system must lower a fluoride test challenge to no more than 1.5 mg/L.

Certified under: NSF/ANSI 58.

Does not work: typical charcoal-based filters, such as pitcher filters.

Key numbers

  • 0.7 mg/L

    U.S. Public Health Service recommendation

    The U.S. Public Health Service recommends 0.7 mg/L for community water systems that add fluoride.

    Verified

  • 1.5 mg/L

    WHO guideline value

    The World Health Organization's guideline value for fluoride in drinking water is 1.5 mg/L.

    Verified

  • 1.5 mg/L

    National Toxicology Program (2024)

    NTP's 2024 monograph concluded, with moderate confidence, that drinking water containing more than 1.5 mg/L is associated with lower IQ in children.

    Verified

  • 2.0 mg/L

    EPA secondary standard (non-enforceable)

    EPA's secondary (non-enforceable) standard for fluoride is 2.0 mg/L, and exceeding it requires a special public notice.

    Verified

  • 4.0 mg/L

    EPA maximum contaminant level (enforceable)

    EPA's enforceable maximum contaminant level (MCL) for fluoride is 4.0 mg/L, and its health goal (MCLG) is also 4.0 mg/L.

    Verified

Affiliate Disclosure: We earn affiliate commissions from purchases made through our links at no extra cost to you. This supports our research and keeps our content free. Learn More

Water filters and their certification listings

Each filter below is shown with its active listings in our copy of the certification directories (as of 2026-10-05), as the certifier lists them. The filters are not ranked.

iSpring RCC7AK-BN

iSpring ยท Reverse osmosis (NSF/ANSI 58 listing)

Certification listings

In our copy of the certification directories (as of 2026-10-05), NSF lists it under NSF/ANSI 58 with the claim "Fluoride", one of 9 claims on that listing. Active certification entries with a fluoride claim: 1 of 1.

Buying Options

Waterdrop G3P800

Waterdrop ยท Reverse osmosis system (Waterdrop's description)

Waterdrop's own product page lists the Waterdrop G3P800 under its reverse osmosis systems, as a tankless reverse osmosis system.

Certification listings

This page shows no certification listing for this filter.

Clearly Filtered Water Pitcher

Clearly Filtered ยท Pitcher

Certification listings

In our copy of the certification directories (as of 2026-10-05), NSF lists it under NSF/ANSI 42 for "Chlorine Reduction", "Taste and Odor Reduction"; WQA lists it under NSF/ANSI 42 for "Aesthetic Chlorine", "Taste and Odor"; WQA also lists it under NSF/ANSI 372. Active certification entries with a fluoride claim: 0 of 3. WQA's page on EPA's lead-free rule names NSF/ANSI 372 as the standard for "Lead content verification".

Buying Options

APEC RO-90

APEC ยท Reverse osmosis (NSF/ANSI 58 listing)

Certification listings

In our copy of the certification directories (as of 2026-10-05), WQA lists it under NSF/ANSI 58 with the claim "Fluoride", one of 12 claims on that listing; WQA also lists it under NSF/ANSI 372. Active certification entries with a fluoride claim: 1 of 2. WQA's page on EPA's lead-free rule names NSF/ANSI 372 as the standard for "Lead content verification".

Buying Options

APEC ROES-50

APEC ยท Reverse osmosis (NSF/ANSI 58 listing)

Certification listings

In our copy of the certification directories (as of 2026-10-05), WQA lists it under NSF/ANSI 58 for "TDS"; WQA also lists it under NSF/ANSI 372. Active certification entries with a fluoride claim: 0 of 2. WQA's page on EPA's lead-free rule names NSF/ANSI 372 as the standard for "Lead content verification".

Aquagear Filter Pitcher

Aquagear ยท Pitcher (Aquagear's description)

Aquagear's own product page calls this pitcher the Aquagear Filter Pitcher.

Certification listings

This page shows no certification listing for this filter.

Buying Options

Home Master TMHP HydroPerfection

Home Master ยท Reverse osmosis system (Home Master's description)

Home Master's own website names its model TMHP the Home Master HydroPerfection Advanced Reverse Osmosis Water Filtration System.

Certification listings

This page shows no certification listing for this filter.

Buying Options

All NSF-certified filters for Fluoride

178 certified ยท 45 consumer filters

Certifier

45 filters

Pentair Residential Filtration, LLC

Under-sinkConserv 75E

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=50 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +8 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkConserv 75S

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=50 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +8 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkEverpure Residential ROM IV

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +8 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkLVRO-75HE

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=50 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +8 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkLVRO-75HE+F

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=50 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +8 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkOmniFilter RO2050

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=50 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +8 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkPentair GRO-350B

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=50 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +11 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkPentair GRO-475B

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=50 ppb, Atrazine, Barium, Cadmium, Chlorine +13 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkPentair GRO-475BP

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=50 ppb, Atrazine, Barium, Cadmium, Chlorine +13 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkPentair GRO-575B

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=50 ppb, Atrazine, Barium, Cadmium, Chlorine +13 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkPentair RO-2550

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=50 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

iSpring Water Systems LLC

Under-sinkRCC7-BLK

Performance

NSF/ANSI 58

Reduces: Asbestos, Barium, Cadmium, Chromium (Trivalent), Copper, Fluoride +3 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkRCC7-BN

Performance

NSF/ANSI 58

Reduces: Asbestos, Barium, Cadmium, Chromium (Trivalent), Copper, Fluoride +3 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkRCC7AK-BLK

Performance

NSF/ANSI 58

Reduces: Asbestos, Barium, Cadmium, Chromium (Trivalent), Copper, Fluoride +3 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkRCC7AK-BN

Performance

NSF/ANSI 58

Reduces: Asbestos, Barium, Cadmium, Chromium (Trivalent), Copper, Fluoride +3 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkRCC7AK-UVBLK

Performance

NSF/ANSI 58

Reduces: Asbestos, Barium, Cadmium, Chromium (Trivalent), Copper, Fluoride +3 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkRCC7AK-UVBN

Performance

NSF/ANSI 58

Reduces: Asbestos, Barium, Cadmium, Chromium (Trivalent), Copper, Fluoride +3 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkRCC7UV

Performance

NSF/ANSI 58

Reduces: Asbestos, Barium, Cadmium, Chromium (Trivalent), Copper, Fluoride +3 more

Certified by NSF ยท Verified 2026-10-05

Aquasential

Under-sinkRO

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Atenolol, Bacteria, Barium, Bisphenol A +33 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkRO (2 yr)

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Atenolol, Bacteria, Barium, Bisphenol A +33 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkSmart RO

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Atenolol, Bacteria, Barium, Bisphenol A +31 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkSmart RO (2 yr)

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Atenolol, Bacteria, Barium, Bisphenol A +31 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkSmart RO (2yr) Nitrate

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Atenolol, Bacteria, Barium, Bisphenol A +33 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkSmart RO Nitrate

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Atenolol, Bacteria, Barium, Bisphenol A +33 more

Certified by WQA ยท Verified 2026-10-04

Solventum Purification Inc.

Under-sink3MRO301

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Under-sink3MRO401

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Under-sink3MRO501

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +11 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkCMTRO-3TFC

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +8 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkCMTRO-75

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkSQC4 Purificare

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

APEC

Under-sinkRO-90

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (300 ppb influent level), Barium, Cadmium, Copper, Fluoride, Hexavalent Chromium +6 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkRO-Hi

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (300 ppb influent level), Barium, Cadmium, Copper, Fluoride, Hexavalent Chromium +6 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkRO-PH90

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (300 ppb influent level), Barium, Cadmium, Copper, Fluoride, Hexavalent Chromium +6 more

Certified by WQA ยท Verified 2026-10-04

Aquasana Inc.

Under-sinkAQ-SFRO

Performance

NSF/ANSI 58

Reduces: Aesthetic Chloramine, Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Asbestos, Atenolol, Barium +35 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkAQ-SFRO2

Performance

NSF/ANSI 58

Reduces: Aesthetic Chloramine, Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Asbestos, Atenolol, Barium +35 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkOptimH2Oโ„ข AQ-RO-3

Performance

NSF/ANSI 58

Reduces: Aesthetic Chloramine, Aesthetic Chlorine, Arsenic (V) (300 ppb influent level), Asbestos, Atenolol, Barium +30 more

Certified by WQA ยท Verified 2026-10-04

GE Appliances, a Haier Company

Under-sinkGNRQ18NBN

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Asbestos, Barium, Cadmium, Chlorine +12 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkGXRQ18NBN

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Asbestos, Barium, Cadmium, Chlorine +12 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkGXRV40TBN

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Asbestos, Barium, Cadmium, Chlorine +12 more

Certified by NSF ยท Verified 2026-10-05

Water Channel Partners

Under-sinkWhirlpool WHAPSRO

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +11 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkWhirlpool WHAROS5

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +11 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkWhirlpool WHER25

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +11 more

Certified by NSF ยท Verified 2026-10-05

Brondell, Inc

Under-sinkRC100

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Barium, Cadmium, Copper, Cyst +9 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkRC250

Performance

NSF/ANSI 58

Reduces: Aesthetic Chloramine, Aesthetic Chlorine, Arsenic (V) (300 ppb influent level), Asbestos, Atenolol, Barium +33 more

Certified by WQA ยท Verified 2026-10-04

Water Channel Partners

Under-sinkBrita Total360 BRDROS

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +11 more

Certified by NSF ยท Verified 2026-10-05

Microline

Under-sinkT.F.C.-335

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkT.F.C.-335FS

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkT.F.C.-335FSX

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkT.F.C.-335X

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkT.F.C.-3PL

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkT.F.C.-3PLX

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkT.F.C.-435

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkT.F.C.-435FFSX

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkT.F.C.-435FSX

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkT.F.C.-435RC

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkT.F.C.-435X

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkT.F.C.-4PL

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkT.F.C.-4PLF

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkT.F.C.-4PLX

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

GHP Group Inc.

Under-sinkPQC3RO

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent), Chromium (Trivalent) +10 more

Certified by NSF

Under-sinkPQC4RO

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent), Chromium (Trivalent) +10 more

Certified by NSF

Under-sinkPQC5RO

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +7 more

Certified by NSF

Under-sinkPUN3RO

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent), Chromium (Trivalent) +10 more

Certified by NSF

Under-sinkPUN4RO

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +6 more

Certified by NSF

Under-sinkV3UNRO

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent), Chromium (Trivalent) +10 more

Certified by NSF

Under-sinkV4UNRO

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +7 more

Certified by NSF

Under-sinkVRO-3Q

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent), Chromium (Trivalent) +10 more

Certified by NSF

Under-sinkVRO-3U

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent), Chromium (Trivalent) +10 more

Certified by NSF

Under-sinkVRO-4Q

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent), Chromium (Trivalent) +10 more

Certified by NSF

Under-sinkVRO-4U

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +7 more

Certified by NSF

Under-sinkVRO-5Q

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +7 more

Certified by NSF

Microfilter Co., Ltd.

Under-sinkM9 3HA RO 100GPD

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkM9 3HA RO 50GPD

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkM9 3HA RO 75GPD

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkM9 4HA RO 100GPD

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkM9 4HA RO 50GPD

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkM9 4HA RO 75GPD

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkM9 4SS RO 100GPD

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkM9 4SS RO 50GPD

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkM9 4SS RO 75GPD

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkM9 5HA RO 100GPD

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkM9 5HA RO 50GPD

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkM9 5HA RO 75GPD

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

EcoWater Systems LLC

Under-sinkERO-175

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkERO-385

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkERO-385-BN

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkERO-385-CP

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkERO-385E

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkERO-385E-BN

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkERO-385E-CP

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkHERO-385-BN

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkHERO-385-CP

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkHERO-385PLUS

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

The LeverEdge

Under-sinkAvantaPure RO-450

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkMAYTAG DRINKING WATER SYSTEM MODEL M-550

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkPro Elite RO-450

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkPro Elite RO-450 With Monitor

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkWestinghouse Drinking Water System A-450

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkWestinghouse Drinking Water System D-550

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkWestinghouse Drinking Water System P-550

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkWestinghouse Drinking Water System R-450

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Hellenbrand Inc.

Under-sinkMillennium MRO-35

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkMillennium MRO-35GF

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkMILLENNIUM PRO S33101-PL6-HB

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkMILLENNIUM PRO S33201-PL6-HB

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkS33301-PL6-HB1

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +6 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkS33401-PL6-HB1

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +6 more

Certified by NSF ยท Verified 2026-10-05

Aqua Systems

Under-sinkAQPC-35

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkAQPC-435

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkS33201-PL6-AS

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkS33401-PL6-AS1

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +6 more

Certified by NSF ยท Verified 2026-10-05

Clover Co., Ltd.

Under-sinkAQVR10

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkAQVR5

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkCLVR10

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkCLVR5

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Coway

Under-sinkCHP-1100R

Performance

NSF/ANSI 58

Reduces: 1,2,3-trichloropropane (1,2,3 TCP), Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Asbestos, Atenolol, Bacteria +35 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkHP-1100R

Performance

NSF/ANSI 58

Reduces: 1,2,3-trichloropropane (1,2,3 TCP), Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Asbestos, Atenolol, Bacteria +35 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkP-160AL

Performance

NSF/ANSI 58

Reduces: 1,2,3-trichloropropane (1,2,3 TCP), Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Atenolol, Barium, Bisphenol A +27 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkP-160L

Performance

NSF/ANSI 58

Reduces: 1,2,3-trichloropropane (1,2,3 TCP), Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Atenolol, Barium, Bisphenol A +27 more

Certified by WQA ยท Verified 2026-10-04

Lancaster Water Treatment

Under-sinkBrita Pro BPLRO-35

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkCRO-350

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkLRO-35

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkPRO-50

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Water Channel Partners

Under-sinkEcodyne ELXROTU

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +11 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkEcopure ECOP30

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +11 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkNorth Star NSRO42C4

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +11 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkNorth Star NSROPS

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +11 more

Certified by NSF ยท Verified 2026-10-05

Kinetico

Under-sinkHYDRO ECO 800 GPD

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Barium, Cadmium, Copper, Fluoride +7 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkK5 Drinking Water Station

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (300 ppb influent level), Bacteria, Barium, Cadmium, Copper +17 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkWM5

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (300 ppb influent level), Barium, Cadmium, Copper, Cyst, Fluoride +7 more

Certified by WQA ยท Verified 2026-10-04

Senwater Systems, LLC.

Under-sinkDRO512

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkTRO508

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkTRO510

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Capital Water Softener, Inc.

Under-sinkAqua Bella CP-TFC-M50-RO

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +6 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkAqua Bella CP-TFC-NM50-RO

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +6 more

Certified by NSF ยท Verified 2026-10-05

Charger Water Treatment Products

Under-sinkClearConnect QC50

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkCWQC50

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Franklin Water Treatment, LLC

Under-sinkPuronics Micromax 6000 TFC

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkPuronics Micromax 6500 TFC

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chlorine, Chromium (Hexavalent) +10 more

Certified by NSF ยท Verified 2026-10-05

Hydronix Water Technology

Under-sinkHDGT-TW50 C

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +9 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkHydro Guard HDGT-45XX

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +8 more

Certified by NSF ยท Verified 2026-10-05

Linton & Associates, Inc dba WaterTech Industries

Under-sinkRO-PPQC

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkRO-PPQC-M

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Marlo Incorporated

Under-sinkTFC-35

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkTFC-35M

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

NECOA

Under-sinkCHP-1100R

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Asbestos, Bacteria, Barium, Cadmium +15 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkHP-1100R

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Asbestos, Bacteria, Barium, Cadmium +15 more

Certified by WQA ยท Verified 2026-10-04

Water-Right / WaterCare

Under-sinkUltroWater

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Under-sinkWater-Rightยฎ WRO-35

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

WaterMax

Under-sinkH3500

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (300 ppb influent level), Barium, Cadmium, Copper, Fluoride, Hexavalent Chromium +8 more

Certified by WQA ยท Verified 2026-10-04

Under-sinkH6000

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (300 ppb influent level), Barium, Cadmium, Copper, Fluoride, Hexavalent Chromium +5 more

Certified by WQA ยท Verified 2026-10-04

A.O. Smith Water Treatment (North American), Inc.

Under-sinkAORO-50

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

AO Smith

Under-sinkHigh Efficiency Reverse Osmosis AOS-HERO-CHR

Performance

NSF/ANSI 58

Reduces: Aesthetic Chloramine, Aesthetic Chlorine, Arsenic (V) (50 ppb influent level), Asbestos, Atenolol, Barium +35 more

Certified by WQA ยท Verified 2026-10-04

AQUA TREATMENT SERVICE, INC.

Under-sinkATS-PRO50-4

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

AquaKinetic

Under-sinkA200

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (300 ppb influent level), Barium, Cadmium, Copper, Cyst +9 more

Certified by WQA ยท Verified 2026-10-04

Aquion, Inc.

Under-sinkRainsoft Ultrefiner Elite

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Atenolol, Barium, Bisphenol A, Cadmium +29 more

Certified by NSF ยท Verified 2026-10-05

ARร‡ELIK A.S

Under-sink3140 SFC

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Atlantic Filter Corporation

Under-sinkHR-35-TFC-4W

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Certiflow Water LLC

Under-sinkELIMINATOR - 350

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +6 more

Certified by NSF ยท Verified 2026-10-05

Frakco, Inc.

Under-sinkAM4QC

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Griesbach Corporation

Under-sink78-0036-XX

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +6 more

Certified by NSF ยท Verified 2026-10-05

HALO Water Systems

Under-sinkH-RO-PLUS

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +9 more

Certified by NSF ยท Verified 2026-10-05

Inter Flo

Under-sinkIF-QPRO

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (50 ppb influent level), Barium, Cadmium, Copper, Fluoride, Hexavalent Chromium +8 more

Certified by WQA ยท Verified 2026-10-04

Kind Water Systems

Under-sinkPRO-RO

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (300 ppb influent level), Barium, Cadmium, Copper, Cyst, Fluoride +7 more

Certified by WQA ยท Verified 2026-10-04

Kinetico Incorporated

Under-sinkHYDRO ECO 600 GPD

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (50 ppb influent level), Barium, Cadmium, Copper, Fluoride, Hexavalent Chromium +4 more

Certified by WQA ยท Verified 2026-10-04

Master Water Conditioning, Inc.

Under-sinkPuro-35T

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Nimbus

Under-sinkWM5-50

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (300 ppb influent level), Barium, Cadmium, Copper, Cyst, Fluoride +7 more

Certified by WQA ยท Verified 2026-10-04

Nugen Pure Water Systems

Under-sinkFQC350

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent), Copper +6 more

Certified by NSF ยท Verified 2026-10-05

Pure Simplicity

Under-sinkPS-5

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (300 ppb influent level), Barium, Cadmium, Copper, Cyst, Fluoride +7 more

Certified by WQA ยท Verified 2026-10-04

Puronics

Under-sinkMicromax 8500

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (300 ppb influent level), Barium, Bisphenol A, Cadmium, Copper +16 more

Certified by WQA ยท Verified 2026-10-04

Quick Change

Under-sinkWQC4RO13-100MT

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (50 ppb influent level), Barium, Cadmium, Copper, Fluoride, Hexavalent Chromium +6 more

Certified by WQA ยท Verified 2026-10-04

R.E. Prescott Co., Inc.

Under-sinkELP50-4

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Rayne Corporation

Under-sinkRaynePure Plus

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Reynolds Water Conditioning

Under-sinkQT-4

Performance

NSF/ANSI 58

Reduces: Arsenic (Pentavalent), Arsenic (Pentavalent)<=300 ppb, Barium, Cadmium, Chromium (Hexavalent), Chromium (Trivalent) +7 more

Certified by NSF ยท Verified 2026-10-05

Storm RO Filtration

Under-sinkSTFP2KHK1RO

Performance

NSF/ANSI 58

Reduces: Aesthetic Chloramine, Aesthetic Chlorine, Arsenic (V) (300 ppb influent level), Atenolol, Barium, Bisphenol A +23 more

Certified by WQA ยท Verified 2026-10-04

Watts

Under-sinkW-525-NF

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (50 ppb influent level), Barium, Cadmium, Copper, Cyst, Fluoride +7 more

Certified by WQA ยท Verified 2026-10-04

Watts Pure H2O

Under-sinkH2O-DWRO300

Performance

NSF/ANSI 58

Reduces: Aesthetic Chlorine, Arsenic (V) (300 ppb influent level), Barium, Cadmium, Copper, Cyst +9 more

Certified by WQA ยท Verified 2026-10-04

Watts Regulator Co.

Under-sinkRO-Pure Plus

Performance

NSF/ANSI 58

Reduces: Arsenic (V) (50 ppb influent level), Barium, Cadmium, Copper, Cyst, Fluoride +11 more

Certified by WQA ยท Verified 2026-10-04

Certified vs claimed

WQA, which runs the Gold Seal testing and certification program, says a certified product has undergone evaluation and testing to verify that it will perform as its certified claims indicate. An NSF/ANSI 58 (reverse osmosis) listing can carry the claim "Fluoride Reduction": EcoWater Systems' ERO-175 listing carries it. To be certified for fluoride reduction under NSF/ANSI 58, a reverse osmosis system must lower a fluoride test challenge to no more than 1.5 mg/L.

On NSF's NSF/ANSI 58 listing for EcoWater Systems, each certified model has its own row with its own claims. Two APEC filters on this page show the difference a model makes: the APEC RO-90, whose WQA listing under NSF/ANSI 58 includes "Fluoride", and APEC's ROES-50, whose WQA listing under NSF/ANSI 58 lists "TDS" in our copy of the certification directories (as of 2026-10-05).

Do water filters remove fluoride? By filter type and brand

Why people filter fluoride

Health authorities set different levels for different effects, shown in the key numbers above. What each authority says at each level, and which questions the evidence leaves open, is on our health-effects page.

The health evidence on fluoride

Frequently Asked Questions About Fluoride Filters

Yes, some do. An NSF/ANSI 58 (reverse osmosis) listing can carry the claim "Fluoride Reduction": EcoWater Systems' ERO-175 listing carries it. Filters on this page with a listed fluoride claim include the iSpring RCC7AK-BN, whose NSF listing under NSF/ANSI 58 includes "Fluoride", and the APEC RO-90, whose WQA listing under NSF/ANSI 58 includes "Fluoride". Idaho DEQ states that typical charcoal-based filters, such as pitcher filters, do not remove fluoride.

Fluoride in Your Local Water

Our ZIP check shows whether fluoride was detected in your local water supply and at what levels.

ZIP Code Water Quality Lookup

Sources

  1. Idaho Department of Environmental Quality. โ€œContaminants in Drinking Waterโ€. https://www.deq.idaho.gov/water-quality/drinking-water/contaminants-in-drinking-water/ (Verified )
  2. Health Canada. โ€œGuidelines for Canadian Drinking Water Quality: Guideline Technical Document โ€“ Fluoride (page 3)โ€. https://www.canada.ca/en/health-canada/services/publications/healthy-living/guidelines-canadian-drinking-water-quality-guideline-technical-document-fluoride/page-3-guidelines-canadian-drinking-water-quality-guideline-technical-document-fluoride.html (Verified )
  3. U.S. Department of Health and Human Services Federal Panel on Community Water Fluoridation (Public Health Reports 2015;130(4):318โ€“331). โ€œU.S. Public Health Service Recommendation for Fluoride Concentration in Drinking Water for the Prevention of Dental Cariesโ€. https://pmc.ncbi.nlm.nih.gov/articles/PMC4547570/ (Verified )
  4. World Health Organization. โ€œGuidelines for drinking-water quality: fourth edition incorporating the first and second addenda (2022)โ€. https://iris.who.int/handle/10665/352532 (Verified )
  5. National Toxicology Program (NIEHS). โ€œFluoride Exposure: Neurodevelopment and Cognitionโ€. https://ntp.niehs.nih.gov/whatwestudy/assessments/noncancer/completed/fluoride (Verified )
  6. U.S. Environmental Protection Agency. โ€œSecondary Drinking Water Standards: Guidance for Nuisance Chemicalsโ€. https://www.epa.gov/sdwa/secondary-drinking-water-standards-guidance-nuisance-chemicals (Verified )
  7. U.S. Environmental Protection Agency. โ€œNational Primary Drinking Water Regulationsโ€. https://www.epa.gov/ground-water-and-drinking-water/national-primary-drinking-water-regulations (Verified )
  8. TapWaterData analysis of the NSF, WQA and IAPMO certification listings. apps/website/src/lib/fluoride/pick-listings.json (Verified )
  9. Waterdrop. โ€œ800 GPD Tankless Reverse Osmosis System - Waterdrop G3P800โ€. https://www.waterdropfilter.com/products/tankless-reverse-osmosis-system-wd-g3p800-w-fc-1 (Verified )
  10. Water Quality Association. โ€œEPA Lead-Free Ruleโ€. https://wqa.org/advocacy/us-legislation-agency-actions/epa-lead-free-rule/ (Verified )
  11. Aquagear. โ€œFilter Pitcherโ€. https://www.drinkaquagear.com/products/waterfiltrationpitcher (Verified )
  12. Home Master. โ€œHome Master Water Filtersโ€. https://www.homemasterfilters.com/ (Verified )
  13. Water Quality Association. โ€œProduct Certificationโ€. https://wqa.org/product-certification/ (Verified )
  14. NSF International. โ€œNSF/ANSI 58 Listings: EcoWater Systems LLCโ€. https://info.nsf.org/Certified/DWTU/Listings.asp?Standard=058&CompanyName=EcoWater+Systems+LLC (Verified )
  15. U.S. EPA, 40 CFR 142.61 (via LII). โ€œ40 CFR ยง 142.61 Variances from the maximum contaminant level for fluorideโ€. https://www.law.cornell.edu/cfr/text/40/142.61 (Verified )

Last reviewed by TapWaterData Editorial. How we verify

Cite this page

"Fluoride Water Filters: Certified Listings". TapWaterData, last reviewed 2026-10-11. https://www.tapwaterdata.com/filters/contaminant/fluoride

Get the Weekly Water Brief

One email a week on water testing, treatment, and what water-quality data means for your home.

One email a week. Unsubscribe anytime.